1. Please check if the bolts are loose or not before the startup of circular vibrating screen, if any looseness,please tighten timely.
2. Running without load for 4 to 6 hours to achieve smooth running of screen body , the vibrator bearing temperature is ≤75℃.
3.After non-load running, please tighten the screw bolt again.
4.Check the fastening condition of the bolts regularly once the operation becomes normal.
5.Check the wearing parts frequently, the damping spring which is damaged or without elasticity,please replace at once. If fracture or wear occur to screen, please tighten or replace the spring timely. Please check the vibration source instructions to adjust,use and maintain the vibration source.
3.After non-load running, please tighten the screw bolt again.
4.Check the fastening condition of the bolts regularly once the operation becomes normal.
5.Check the wearing parts frequently, the damping spring which is damaged or without elasticity,please replace at once. If fracture or wear occur to screen, please tighten or replace the spring timely. Please check the vibration source instructions to adjust,use and maintain the vibration source.
6.Stop the machine after the material on screen surface are completely discharged.
Hope above mentioned are helpful,more information please click: www.pkmachinery.com
没有评论:
发表评论